11 Freebournes Road
Bauder reinforced bituminous waterproofing system with BauderSOLAR F
Synopsis
A large derelict warehouse located in Witham has undergone major renovation to transform it into a storage centre for Essex County Council that will assist its services and benefit the local community. The refurbishment works were designed and project managed by Lambert Smith Hampton on behalf of the client, who wanted the building to act as a benchmark for sustainability with the roof playing an integral part in achieving this through the addition of solar panels.
Bauder Building Board
Project Name:
|
11 Freebournes Road
|
Location:
|
Witham, Essex
|
Roof Size:
|
5,200m²
|
Client:
|
Essex County Council
|
Project Manager:
|
Lambert Smith Hampton
|
Approved Contractor:
|
Acclaim Contracts
|
PV Installer:
|
CJ Solar
|
Environmental focus:
|
Solar PV
|
The specification
Working closely with the client, Bauder performed a comprehensive roof evaluation survey to identify the full extent of water ingress being experienced and to confirm the suitability of adding solar. The bespoke survey report highlighted that the roof needed to be stripped back to its original deck, before being waterproofed with over 5,200m2 of Bauder’s reinforced bitumen system by Acclaim Contracts. 588 solar PV modules were then fitted onto the roof by electrical installer CJ Solar, enabling the client to generate at least 134.70 Megawatt Hours of solar power each year.
Products applied
BauderSOLAR F
Integrated photovoltaic system, where the modules and the substructure are combined to form a single unit, which is secured to the roof without any penetration of the waterproofing or roof deck.
System installed
Reinforced Bitumen Membrane System
1 Reinforced bitumen membrane
|
Torch applied, elastomeric bitumen capping sheet
|
2 BauderPIR M 60
|
Rigid urethane foam insulation faced on both sides with aluminium foil.
|
3 BauderPIR FA-TE
|
Torch applied air and vapour control layer
|
Advocacy
Julian Sanchez, Commissioning Delivery Manager for Essex County Council:
“We actively look for opportunities to implement renewable energy and knew that this storage facility lent itself well to PV retrofit. Our system selection process involved the due diligence you would expect from a local authority and we decided to go with Bauder because of its comprehensive system portfolio that meant we could have a single source supply and all-inclusive guarantee; giving us complete confidence in the roof’s performance.”