System Airtech

Specifically developed to deliver a torch-free installation where site conditions prohibit the use of open-flame. The system combines self-adhesive membranes and hot air welding.

System Airtech achieves a CCPI mark which recognises that any claims made about it have been independently assessed across 11 clauses, providing greater clarity by offering improved product information. This gives specifiers confidence in the knowledge that they will have unambiguous information when deciding which of our systems is best for their new build or refurbishment project.

When to specify

Airtech is a fully bonded system suitable for new build and refurbishment projects with a choice of insulations for warm roof construction. The system can also be used as a two-layer overlay to an existing roof that is thermally reliable and still meets current standards.

The system uses the BauderTEC KSO range of SBS modified cap sheets with three slate mineral colour finishes and installation that embraces self-adhesive membranes and hot air welding at all detailing and laps.

Plus points

■□ Entire system features flame-free installation.
■□ Tested bond strength for adhesives.
■□ Comprehensive range of guarantee packages to fulfil cover requirements for the project (dependant on system/product selection). For more information contact our technical dept for a sample guarantee outlining cover level, terms and conditions.

Verified properties

CCPI Verification 0007700023/1025:
■□ This systems CCPI mark provides accuracy of data delivering assurance to specifiers. 
EPD Certification:
■□ Bitumen Membranes.
■□ Insulations.
 

 

  Function Product name Thickness
(mm) 
Weight
(kg/m2)
1 Cap sheet BauderTEC KSO-P SN (charcoal grey)
BauderTEC KSO SN (grey slate)
BauderTEC KSO ALP SN (brown)
4 5.2
2 Underlayer BauderTEC KSA DUO 3 3.5
3 Insulation (0.15) BauderPIR FA-TE (shown) 140  4.2
  Warm roof insulation options BauderPIR FA tapered
BauderVIP
BauderROCK flatboard
BauderROCK tapered
BauderGLAS
variable variable
  Insulation
attachment
method
Bauder PU Tin Adhesive nominal 0.16
5 Air and vapour
control layer
(AVCL)
BauderTEC KSD FBS 2.5 2.5
  Primer Varies depending upon
substrate type - please refer
to specification
nominal nominal
System build-up 149.5 15.56
In-depth and up-to-date product specific technical data is available for each element within a system.
Download from our technical-centre


Cap sheet colours 

BauderTEC KSO SN cap sheet is available in grey slate.

Grey slate

BauderTEC KSO-P SN cap sheet is available in charcoal grey.

Charcoal grey

BauderTEC KSO ALP SN cap sheet is available in brown.

Brown

Approvals, certification and guarantee

■□ Comprehensive range of guarantee packages to fulfil cover requirements for the project (dependant on system/product
      selection). For more information contact our technical department for a sample guarantee outlining cover level, terms
      and conditions.
■□ CCPI Verification Number 0007700023/1025 for Bauder System Airtech.
■□ BS EN 13707:2004 Reinforced Bitumen Membrane Sheets.
■□ Stated permutations hold fire classification BROOF(t4) for compliance with building regulations under TS 1187 test method 4 for external fire exposure to roofs. Airtech is deemed ‘unrestricted’ and suitable for use on any part of a roof. Bauder Fire Test Reports are available on request, please contact [email protected]
View certifications here ►

 

Installation and maintenance

The quality and experience of the installing operative is paramount to ensuring a successful project. Bauder Approved Contractors are the only people fully trained and certified to install our products. They provide the necessary experience that our exceptional guarantee demands.
Go to approved contractor information ►
Go to maintenance advice ►
 

Bauder Torch-Free Detailing Methods 

Safe2Torch industry initiativeOur torch-free detail design specifically delivers secure safe application techniques in the vicinity of combustible construction materials located on, or connected to, the roof such as timber substrates or upstands; abutments to cladding, roof tiles, slates or thatch; or even debris such as dry leaf material that is at risk from ignition.  The application methods meet NFRC Guidance Document 'Safe2Torch'.

Go to Torch-Free Detailing ►
 

Contact us today about your project

Each project is unique in its requirements, but we have case studies and examples of our work available for you to look at. If you are looking for a bituminous membrane roof system, then get in touch with our team to discuss your project’s individual needs.

 



Downloads